Common Faults And Troubleshooting Methods Of PE Pipe Fittings Electric

Mar 22, 2021

Leave a message

After customers purchase PE pipe fittings, the most important thing is the construction. Due to the changeable construction environment, special equipment for PE pipes such as electric fusion welding machine and hot fusion butt jointing machine may fail. Today, the editor summarizes some common problems. , Can help you solve the pipeline equipment problem as soon as possible, and ensure the safety of pipeline welding.

HDPE Pipe Butt Fusion Welder

Electric Fusion Welding MachineFailure phenomenonPossible Causeselimination method
No powerFuse burned out, power interface problemReplace parts, reconnect
After power on, the display does not show, the screen is blurred, and the machine beepsThe display screen is damaged (moisture, heat, impact, aging, disconnection of wiring)Rewiring, replacing the display
The current cannot riseThe external power supply is undervoltage, the power cord is laid too longCheck external power connection and re-lay
Can not work normally according to the set parameters when the power is connectedThe first stage current parameter setting is too lowIncrease the first section of current parameters, the time is less than 30S, and then continue to perform normal parameter welding
Display welding abnormalityPE pipe fitting heating element short circuitStop welding, wait until it cools down before welding
Display output open circuit, resistance value exceeds the lower limitAbnormal PE pipe fittingsCheck the PE pipe fittings and replace the pipe fittings for welding
Abnormal welding process, hot terminalThe copper cap of the output wire is agingCorrect the copper cap or replace with new accessories
Display overcurrent, overvoltageExternal power supply problemCheck the external power supply and rewire
Butt Fusion MachineThe motor works but the hydraulic drive is invalidThe hydraulic oil is not enough at the nominal positionCheck the hydraulic oil and select the specified hydraulic oil to supplement
Electric control box meter does not displayDamaged accessories or disconnected wiresCheck accessories and lines for replacement or repair
The heating plate does not heat or the temperature is not controlledThe line is off or the temperature controller is damagedCheck the wiring and replace the accessories
Oil leakage at the high pressure pipe interfaceDamaged quick plugReplace the quick plug
Component is not workingPoor contact of aviation plugs and socketsCheck and replace accessories
The motor does not workWiring is off, motor is damagedCheck and repair

The above is the fault reason and repair method of PE pipe electric fusion and hot fusion butt joint machine summarized by the editor. I hope to help everyone and have more PE pipe problems.